APC Rack PDU 2G power distribution unit (PDU) 30 AC outlet(s) Black

APC Rack PDU 2G. PDU types: Metered, Mounting: Horizontal/Vertical, Product color: Black. AC outlets quantity: 30 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, NEMA 5–20R, Input connection type: NEMA L14-30P. LED indicators: Alarm, Cable length: 118.1" (3 m), Certification: cUL Listed, FCC Part 15 Class A, ICES-003, UL 60950-1, UL Listed, REACH. Monitoring: Current. Nominal input voltage: 120-208 V, Maximum current: 30 A, AC input frequency: 50 - 60 Hz
Manufacturer: APC
Availability: In stock
SKU: 4123301
Manufacturer part number: AP8870
MSRP: $1,270.00
$781.50
Rack PDU 2G, Metered, ZeroU, 30A, 100-120/200-240V, (16) 5-20R (12) C13 (2) C19 APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency. Includes : Installation guide , Rack Mounting brackets , Safety guide , Serial configuration cable
Rack PDU 2G, Metered, ZeroU, 30A, 100-120/200-240V, (16) 5-20R (12) C13 (2) C19 APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency. Includes : Installation guide , Rack Mounting brackets , Safety guide , Serial configuration cable
Products specifications
Attribute nameAttribute value
Load Capacity5760 VA
MountingHorizontal/Vertical
Packaging contentInstallation guide, Rack Mounting brackets, Safety guide, Serial configuration cable
Design
CertificationcUL Listed, FCC Part 15 Class A, ICES-003, UL 60950-1, UL Listed, REACH
Operational conditions
Operating temperature (T-T)-5 - 45 °C
Power
Maximum total current draw per phase24 A
Nominal input voltage120-208 V
Weight & dimensions
Dimensions (WxDxH)2.17 x 1.73 x 70.5"
Features
LED indicatorsAlarm
Other features
Input connection typeNEMA L14-30P
Package dimensions (WxDxH)6.46 x 4.25 x 79"