APC Smart-UPS RT 10,000VA 208V w/ (2) 208V to 120V Step-Down Transformer 10 kVA 8000 W

APC Smart-UPS RT 10,000VA 208V w/ (2) 208V to 120V Step-Down Transformer. Output power capacity: 10 kVA, Output power: 8000 W, Input frequency: 50/60 Hz. Battery technology: Sealed Lead Acid (VRLA), Typical backup time at full load: 4.9 min, Typical backup time at half load: 14.8 min. Product color: Black, Certification: CSA,FCC Part 15 Class A,UL 1778. Weight: 495.2 lbs (224.6 kg). Interface: DB-9 RS-232, RJ-45 10/100 Base-T, Smart-Slot, Output connections: 16x NEMA 5-20R 2x NEMA L14-30R 6x NEMA L6-20R 3x NEMA L6-30R, Input connection type: 3-wire
Manufacturer: APC
Availability: Out of Stock - on backorder and will be dispatched once in stock.
SKU: 1014510
Manufacturer part number: SURT10000XLT-2TF3
MSRP: $10,440.00
$8,037.74
Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS overload condition or fault. Scalable runtime Allows additional run time to be quickly added as needed. Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging. Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced. Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power. Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature.
Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS overload condition or fault. Scalable runtime Allows additional run time to be quickly added as needed. Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging. Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced. Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power. Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature.
Products specifications
Attribute nameAttribute value
Weight495.2 lbs
Battery Recharge Time2.2 h
Output voltage noteConfigurable for 208 or 240 nominal output voltage
Design
CertificationCSA,FCC Part 15 Class A,UL 1778
Weight & dimensions
Dimensions (WxDxH)20.6 x 29 x 17"
Features
Output power8000 W
Other features
Output connections16x NEMA 5-20R 2x NEMA L14-30R 6x NEMA L6-20R 3x NEMA L6-30R
Input connection type3-wire
Battery
Typical backup time at full load4.9 min
Typical backup time at half load14.8 min