Tripp Lite S3MT-20K480V isolation transformer

Tripp Lite S3MT-20K480V. AC inlet type: Hardwire, AC outlet types: Hardwire, AC input voltage: 480 V. Width: 17.4" (442 mm), Depth: 33.5" (850.9 mm), Height: 47.2" (1198.9 mm). Quantity per master (outer) case: 1 pc(s), Master (outer) case width: 22.2" (563.9 mm), Master (outer) case length: 37.8" (960.1 mm)
Manufacturer: Tripp Lite
Availability: Out of Stock - on backorder and will be dispatched once in stock.
SKU: 6257934
Manufacturer part number: S3MT-20K480V
MSRP: $6,375.60
$4,496.71
Get Complete Step-Down and Isolation Protection and Prevent Power Disruption Tripp Lite’s S3MT-20K480V 20kVA/kW transformer offers line isolation and protection to the connected 3-phase UPS system and its load. It isolates the UPS and connected components from line surges and spikes caused by utility power disruptions that can damage equipment or corrupt data. The step-down input isolation transformer is ideal for 4-wire (3Ph+N+PE) IT loads in government, manufacturing, healthcare and corporate settings with a 480V electrical feed and 208/120V equipment. Performs with High Efficiency up to 96.5% Not only is the S3MT-20K480V very efficient, with up to 96.5 percent efficiency, but it is also very quiet with a noise profile less than 65 dBA. A built-in circuit breaker on the output side helps prevent dangerous power overloads. Two ball-bearing cooling fans help prevent overheating. An overheat-sensing relay and switch combine with a red LED indicator to provide over-temperature warning and overheating protection. Small Footprint for Quick Installation in a Compact Space The compact footprint enables installation of the S3MT-20K480V with minimal space. The rugged stainless steel housing ships ready for immediate installation with a compatible 10–20kVA/kW Tripp Lite S3M-Series 3-phase UPS system.
Get Complete Step-Down and Isolation Protection and Prevent Power Disruption Tripp Lite’s S3MT-20K480V 20kVA/kW transformer offers line isolation and protection to the connected 3-phase UPS system and its load. It isolates the UPS and connected components from line surges and spikes caused by utility power disruptions that can damage equipment or corrupt data. The step-down input isolation transformer is ideal for 4-wire (3Ph+N+PE) IT loads in government, manufacturing, healthcare and corporate settings with a 480V electrical feed and 208/120V equipment. Performs with High Efficiency up to 96.5% Not only is the S3MT-20K480V very efficient, with up to 96.5 percent efficiency, but it is also very quiet with a noise profile less than 65 dBA. A built-in circuit breaker on the output side helps prevent dangerous power overloads. Two ball-bearing cooling fans help prevent overheating. An overheat-sensing relay and switch combine with a red LED indicator to provide over-temperature warning and overheating protection. Small Footprint for Quick Installation in a Compact Space The compact footprint enables installation of the S3MT-20K480V with minimal space. The rugged stainless steel housing ships ready for immediate installation with a compatible 10–20kVA/kW Tripp Lite S3M-Series 3-phase UPS system.
Products specifications
Attribute nameAttribute value
Heat dissipation3413 BTU/h
Input current (input transformer)35 A
Output current (input transformer)75 A
Inrush current (input transformer)300 A
Efficiency (@half load)96.5 %
Height47.2"
Weight429.9 lbs
Load Capacity20000 VA
Master (outer) case weight485 lbs
Master (outer) case length37.8"
Master (outer) case height54.8"
Number of input phases3
AC inlet typeHardwire
AC output voltage120 - 208 V
Number of output phases3
Country of OriginChina
Width17.4"
Depth33.5"
Housing ColorBlack
Master (outer) case width22.2"
Packaging data
Package width22.2"
Package depth37.8"
Package height54.8"
Package weight485 lbs
Ports & interfaces
AC outlet typesHardwire
Design
Form factorTower
Power
AC input voltage480 V
AC input frequency50/60 Hz
Features
Cooling typeFan
Noise level65 dB
Number of fans2 fan(s)
LED indicatorsY
Efficiency95 %
Packaging content
ManualY
Performance
Fan diameter4.72"
Logistics data
Quantity per master (outer) case1 pc(s)
Product tags
  • (56828)